NOTE: This manual is for three models, which are distinguished by model A, B and C hereinafter. A B C Emissivity adjustable Temperature Alarmin
1. Safety Information ● Please read the following information carefully before using the meter. ● Safety symbols:- Danger/Important Information prom
1. Sighting Groove 2. Laser orifice 3. Detector orifice 4. Tripod nut 5. Trigger 6. Battery cover 7. LCD 8. Laser button 9. Emissivity reductio
Model B: (Emissivity adjustable) 1. Laser-On Indicator 2. The first temperature display 3. Average value indicator 4. MAX/MIN indicator 5
5. Measurement Principle Infrared thermometers detect infrared energy emitted by objects. The instrument focuses energy through its lens, changing the
7. Distance to Spot Ratio The thermometer has an optical angle and spot size as shown below. Object Focus tube Sensor The target s
Substance Emissivity Substance EmissivityAsphaltum 0.90 - 0.98 Plastic 0.8 – 0.95 Concrete 0.70 – 0.75 Plastic film 0.5 – 0.95 Sand 0.8 – 0.9
9. Temperature alarming function (Only model C) Press “MODE” button, and when the “ALARM” symbol appears on LCD, you can set the alarming temperature
12. Accessories 9V battery………………………….1 pcs Operating manual………………...1 pcs Carrying bag………………………1 pcs 15